Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

Potterton Prima F50?

Hi guys - I have followed the common problems with these boilers (ie PCB issues) but sadly this isn't working for me - can anyone help please?! I am reasonably competent at electronics and have replaced all three troublesome caps and checked the PCB closely for other issues but all seems well. Still no starting up though. When boiler is turned on I get the fan whirring and if I turn the boiler heat control know slowly from 0 to max I can hear one relay/switch click followed by another but nothing else happens. Boiler has been working fine for the three years we have lived here and was serviced a few weeks ago but worked fine non-stop since the service up to now.
Max, March 2012
Update - seems the main fan in the boiler has stopped turning. If I blow into the red pipe the pilot valve opens and the spark generator sparks - BUT the sp1 on the PCB sparks, none appear at the pilot light. If I manually light it the pilot lights but the main gas burner does not and as soon as the sparker stops sparking the pilot goes out. Obviously I will need a new fan but are there others issues here too?

Max p, March 2012