3 hours ago Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Katie Bond asked ... Fixing auto threader on Baby Lock Enlighten Overlocker?    |    Chris. asked ... Miele W800 novotronic washing machine?    |    Larry asked ... How to stop my steam iron from leaking. Model dw2463 Rowenta?    |    Click here to ask your question

How can I relace the automaticair vent.? Ideal HE24?

Had a leak which originated from auto air vent. Wall fuse blown because water dripped down onto control panel and board. Engineer came at callout cost £78 and identified auto air vent at fault. Would have to ask manager how to replace. Never came back. Took panels aout and dried, fitted back, installed fuse, OK.
Still need to change auto vent. How difficult, how long ?
James T, October 2012
AAV located at rear of heat exchanger behind flue turret manifold
very difficult to access
would need to remove FAN & burner plate to gain access
possible for experienced gas engineer to remove & fit AAV in 30 minutes [provided AAV hasnt seized onto HEX housing]

seems a bit extortionate to charge someone £78 & not repair/fix the boiler

Q, October 2012