make sure the diverter valve on the right hand side is pulled fully inwards and both microswitches on it are made. If so, the servo valve is not in hot water mode. Next the fan should run and air pressure switch should make so long as the boiler isn't up to temperature or in time delay mode (air pressure switch can be linked out to prove it) If this is all ok, due to the fault only being apparent on heating, it is most probably a PCB problem. The real problem lies it deciding which PCB! In this case i would go for the thermostat PCB or the mother board. If only changing one of these PCBs you will need to know if it is a hybrid model or not. Remove the knob from the thermostat and if the spindle is white it is hybrid, if it's anything else it is non hybrid. If changing both PCBs as a pair, this doesn't matter. Good luck!
Andy, heating engineer., December 2006