andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

Baxi Combi HE heating does not turn off?

My boiler above is only 6 months old but now even when we turn the thermostat right down the heating does not go off and even when it did go off at night before this current problem, it then came back on in the early hours with the thermostat turned right down. Please help
Helen, April 2013
If it comes on when water is used than diverter valve letting by or if cannot turn of even water is not used than faulty micro switch on front section of diverter valve

k, April 2013
link Click here to see other fixes for Baxi Combi HE.