GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

vokera excell 80sp: re-ignited pilot light will not stay on?

Our 'vokera excell 80sp boiler' was turned off, because the pressure gauge hit 3.
It hit 3 because too much water was let into the system, when trying to run hot water at a constant.
The problem now is that the pilot light will not stay lit after the 'gas control knob' is released?
Is there a safety release button..? or such like as the pressure gauge shows its dropped back to normal level?
jack, November 2006
Thanks Pete, i appreciate the advice, i will try that.

jack, November 2006
Sounds like you need to replace the thermocouple, it looks like a piece of thin copper pipe and is in the flame of the pilot light. Sometimes, removing it and cleaning the connection (where it fixes into the control box) with a pencil eraser will sort it. Make sure it is in the flame when you refit it. It is a safety device, designed to cut the gas if the flame goes out.
Pete.. service engineer (oilysump@aol.com)

Pete, November 2006