Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

vokera excell 80sp: re-ignited pilot light will not stay on?

Our 'vokera excell 80sp boiler' was turned off, because the pressure gauge hit 3.
It hit 3 because too much water was let into the system, when trying to run hot water at a constant.
The problem now is that the pilot light will not stay lit after the 'gas control knob' is released?
Is there a safety release button..? or such like as the pressure gauge shows its dropped back to normal level?
jack, November 2006
Thanks Pete, i appreciate the advice, i will try that.

jack, November 2006
Sounds like you need to replace the thermocouple, it looks like a piece of thin copper pipe and is in the flame of the pilot light. Sometimes, removing it and cleaning the connection (where it fixes into the control box) with a pencil eraser will sort it. Make sure it is in the flame when you refit it. It is a safety device, designed to cut the gas if the flame goes out.
Pete.. service engineer (oilysump@aol.com)

Pete, November 2006