Andrew - C asked ... Stannah 400?    |    Liam asked ... Belts for old WEBB Mower?    |    Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    Click here to ask your question

prisma combi?

i am losing pressure on my prisma 24SE combi and have to keep filling regular looking at some of the other answers to this problem it seems i need to repressure the expansion vessel where can i find this on this model and is it pressured with a footpump the same
PETER@norman76.fsnet.co.uk, December 2006
if you found water from expansion vessel it needs a replacement vessel

John Thompson Heating, March 2007
IS THE 1 BAR PRESSURE ON THE CLOCK GAUGE ON THE BOILER OR THE GAUGE ON THE FOOTPUMP ALSO DOES THE SYSTEM HAVE TO BE DRAINED OR JUST TAKE ENOUGH OUT SO CLOCK GAUGE ON BOILER READS NOUGHT ; I FOUND VALVE IT IS AT THE FRONT ON THE TOP IT HAD WATER SEEPING OUT

PETER@norman76.fsnet.co.uk, December 2006
The expansion vessel can be found on the rear of the appliance, the bit closest to the wall...

I believe (If memory serves me correct) you can find the schraeder valve in the top left hand side of the appliance.

It should be 1Bar with the boiler empty of water.

GasAid.co.uk, December 2006