3 hours ago Karen asked ... Royal 480nt cash register?    |    andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    Click here to ask your question

Ideal isar 30 combi/boiler?

boiler trips out on F/l display
On resetting usually takes 3 attempts to fire up
Fault occurs between every 1 to 5 days
Graham B, September 2015
LF
Multiple causes
Could be
Ignition electrode 173528
Detection electrode 173529
Detection lead 173512
Spark generator 173538
Condensate trap 174244
Flueing issues
Gas supply problems
Wiring harness problems
Or maybe even the pcb

The list of possible causes for LF are numerous
& each one requires a different strategy to test it

The boiler manual goes into great detail as to how try to test each component
Provided you have a multimeter a flue gas analyser & a manometer

Q, September 2015