Andrew - C asked ... Stannah 400?    |    Liam asked ... Belts for old WEBB Mower?    |    Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    Click here to ask your question

prisma combi?

i put a question in recently asking do i drain the system until i have no pressure showing on the clock gauge and then pump this up through the valve at the top until i get 1 bar pressure on the clock on the boiler
P, December 2006
thanks gas aid i did drain water out until pressure clock read 0 when i tried to inflate presure it was registering on the presure clock on boiler does this mean there is still water in system what method should i use to drain boiler

PETER@norman76.fsnet.co.uk, December 2006
I presume you are talking about the expansion vessel...

You need to drain the boiler and pump the expansion vessel up to 1 Bar... You need to do this with a foot pump with it's own gauge... You do not want the boiler to register anything whilst pumping up the vessel, once at a bar... You then need to reconnect the boiler and fill the system to 1bar as shown by the boiler with water.

GasAid.co.uk, December 2006