3 hours ago vic asked ... How do l get my vauxhall combo radio to work with MP3?    |    Cass asked ... Replacing full bulb housing unit in Neff oven?    |    Pádraig O Sabhain asked ... How to fix Kenwood Slimline Dishwasher KDW45X20 with a F1 Er?    |    keith asked ... How to reset after battery change?    |    Carol asked ... How to remove roller from lawnmower?    |    Click here to ask your question

BAXI Combi 105E DHW VALVE leak?

I have a leak from the DHW pushrod hole (the one which comes out horizontally to the switch). Do I need to drain the entire system or just shut off supply and run taps before attempting to repair/replace the diaphram mechanism?

Thanks.
Darren, January 2007
Did the job, easy no probs for 3 months now. Bought Diaphram kit £8.00 which came with new brass nut and seal and a small grommit. Switched off water mains/power to boiler and removed front switch and nut(carefull to stop water falling on PCB), cleaned rod and slid on grommit with silicone grease. Reassembled and switched on water and power. Leak fixed!

Darren, March 2007
If its the DHW diaphragm (Faces you on the left hand side) that you are talking about, then all you need to do is turn off the mains water supply and electricity. Open a tap to relieve the pressure and job done.

GasAid.co.uk, January 2007
link Click here to see other fixes for Baxi 105E.