Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Noman asked ... Reverse light switch?    |    Suzie asked ... Stuck Feed dog?    |    Click here to ask your question

combie boiler pressure keeps going down?

my vokera excell boilers pressure drops to 0 when i have had
the central heating on i then have to keep topping the
pressure up after the heating has gone off -- whats wrong
help
fran, January 2007
If the pressure has totaly dropped and preventing boiler to fire again after the boiler has been in use, The problem indicates that there are expansion issues with your boiler, when the pressure has dropped to 0 look down the back of the boiler and you will see a red expansion vessel, (you will have to go in from the top) remove the cap and check the pressure with a tyre pressure gauge. if the pressure in the expansion vessel is not 1bar- around 14psi then the vessel will req re-pressurising with a foot pump to 1bar- an indication of this problem is the pressure relief pipe outside the house will run when boiler in operation

chris, February 2007
you have a leak in pipe work or prv leaking

hi-spec plumbing, January 2007
link Click here to see other fixes for Vokera.