Check air flow sensor if boiler is working with fan at slow speed and minimum flame level is observed when hot water is being drawn.The sensor is a box containing 2 thermistors, one of which has air drawn past it by the flue fan. This results in a voltage being produced proportional to the fan speed. If the voltage is low the boiler thinks the fan is too slow and will not allow full gas status.For some reason the fault is more critical with hot water than with central heating.This is a personal experience with my own boiler Midas SI. Hope this helps.
alan senior, February 2007