4 hours ago Jo asked ... How to engage clutch on old sewing machine to engage needle?    |    Jacky asked ... Miele Vacuum cleaner?    |    Ben asked ... Toyota Yaris French or Japanese?    |    Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Click here to ask your question

How can I re-pressurise my Bexi Combi 80e?

I need to re-pressurise the system to get my hot water. It says to call an engineer but I'm sure it is as simple as pressing a few buttons in the correct manner.

Please Help.

Beggining to smell!!!
Jonezee, March 2007
I agree with steve --there should be the filling loop under or near the boiler ..

dave broadbent, June 2007
First...I'm no plumber!

BUT on our 105E if you look under the boiler you will hopefully see 2 taps/valves joined by a flexible tube (silver?).

If these are there open one valve, then the other SLOWLY. You should hear the water going in. Watch the pressure guage and allow to pressurise to about 1 bar.

Perhaps after the boiler MAY need resetting as I believe they shut down when the pressure is about 0.5 bar.

Steve, March 2007