GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

I have a alpha 240e combi boiler about eight years old?

I have noticed recently that radiator is getting hot when running hot water with boiler set on water only.also the water temp is not constant. When set to heating and water there is a big gurgle in bathroom radiator as soon as shower is turned off. I guess it could be the diverter valve but any ideas if it could be caused by anything else ?
Nigel, March 2007
i would agree with you too, had same problem on sime boiler. diaphragm in diverter valve perished, cost about £1 to fix

dave, March 2007