2 hours ago Jo asked ... How to engage clutch on old sewing machine to engage needle?    |    Jacky asked ... Miele Vacuum cleaner?    |    Ben asked ... Toyota Yaris French or Japanese?    |    Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Click here to ask your question

I have a constant leak from my Vaillant boiler?

My Vaillant boiler has a constant fast drip from the outflow pipe.
The water pressure is at zero if I try to adjust this up the drip becomes a constant flow.
What can I do?
kevbrad, June 2007
the pressure relief valve sounds like it is stuck open ,you need to recharge ther expansion vessel and replace the valve .then check the filling loop is not passing and refill the boiler to 1.2 bar pressure

pete, June 2007
you need to renew the pressure relief valve