GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

Puma 80 overheats and shutsdown when DHW switched off?

This 8 year old Potterton Puma 80 has had first a new diverter valve fitted, and now a circuit board, but still overheats (burner remains on) and shutsdown to safety when DHW tap is switched off- but only if the boiler was previously heating the rads.
DHW works normally otherwise, but central heating sometimes won't light and switches off after a while. I think it is a little scaled up but would like to get a few more years out of it.
I have flushed the system, cured any leaks, and checked the water flow switch (which makes a circuit when a tap is opened and vice verse, and has 22.6v).
Should I try changing the pump?
James, February 2005
For anyone experiencing the same problem it turned out to be the CH temp sensor. A very simple part to fit.

James, March 2005
Update- CH not coming on at all now. I had a look at the frost stat- doesn't seem to make a difference. Any new ideas, or does anyone know a heating engineer really experienced in these boilers?

James, February 2005
SOUNDS LIKE FROST STAT IS CLOSED HAD SAME PROBLEM FEW WEEKS AGO

STEVE BH HEATING, February 2005