Andrew asked ... Jcb cordless 20v combi drill?    |    marc asked ... La machine 1 type 813?    |    Andrew - C asked ... Stannah 400?    |    Liam asked ... Belts for old WEBB Mower?    |    Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Click here to ask your question

marathon 100b boiler?

my boiler went off on its own while running normaly. i assumed the thermocouple has stoped working so i replaced it but the pilot will not stay on. how can i check the thermocouple is giving an output.what is the value of its output ie. voltage and what does it operate or is there a problem some where else
maj, August 2007
first make sure the boiler is not in demand whilst trying to light it then if you establish a pilot but everytime you release the pilot button it goes out you will find the gas valve is stuck closed very common new gas valve required

steve w

steve w, August 2007