Felix asked ... Hitachi vt-m70em?    |    Katie Bond asked ... Fixing auto threader on Baby Lock Enlighten Overlocker?    |    Chris. asked ... Miele W800 novotronic washing machine?    |    Larry asked ... How to stop my steam iron from leaking. Model dw2463 Rowenta?    |    HT asked ... Radio code Philips 22RC200/35?    |    Click here to ask your question

How can I fix my Protherm 80E boiler?

The boiler is currently showing F1, and losing pressure after heating switches off - despite numerous plumbers looking at it, it still remains - after speaking to technical helpline, they advised it could be sensor electrode - has anybody had similar problems, and does this rectify the fault.
J Newton, September 2007
F1 no flame detected: Boiler will go to this code if it fails to fire after a short peroid of time.If low pressure most combi's won't fire. Check for leaks . Main cause is a slow dripping discharge pipe.Would need if this is the case a new blow off valve.Other main cause of 80E failures are flue pipes that have come apart.you would need to take boiler apart to check this.NOT recommended to anyone other than corgi reg fitters.I have fitted and repaired 100's of these.

Tony Davis, September 2007