4 hours ago wendy asked ... Old Creda Solar Plus Cooker will not come on?    |    Nick asked ... Oven spark Continuing after lit?    |    Andrew asked ... Jcb cordless 20v combi drill?    |    marc asked ... La machine 1 type 813?    |    Andrew - C asked ... Stannah 400?    |    Click here to ask your question

Worcester Oil Boiler Fan Motor Will Not Run?

Our old Worcester boiler locked out at the weekend and will not restart. What i have found is the fan motor will not run when bolted into the burner,if removed and sat on the floor or held in my hand it will start every time. I have checked the fuel pump and can find nothing wrong there,the fuel pump can be rotated freely by hand with very light resistance.
I suspect the capacitor on the motor,any thoughts?
Mikey, October 2007
Change the capacitor (for all the cost of it).

If that doesn't work it can only be the motor, as long as you're sure the pump is OK.

Oil pumps are prone to go faulty more than motors. Make absolutely sure you are only turning the shaft of the pump the correct way. Danfoss BFP ??L3 or R3. The "L" denotes the shaft turns anticlockwise and the "R" denotes that the shaft turns clockwise. Make sure there are absolutely no sticking or dry parts when you turn the shaft.

Hope some of this helps

Martin

Martin, October 2007