Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

any ideas on a ravenheat 820/20 combi boiler?

The boiler shuts off about 5 minutes after running a bath,when the hot water tap is opened afterwards the water is boiling hot.Everything runs fine when the heating is on.The hot water stat is working ok.
Sam Ward, October 2007
hot water stat should let burner fire at max 8mbar and min 1.5mbar. turn on tap, observe burner and when water starts to get hot slowly turn dhw stat down, it should give an audible click and burner flame should reduce, turn it back up and flame should go up accordingly. if it doesnt click then stat faulty, if it does click but flame size stays the same then modureg on gas valve maybe faulty.

paul martin, October 2007
link Click here to see other fixes for Ravenheat.