Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Noman asked ... Reverse light switch?    |    Suzie asked ... Stuck Feed dog?    |    Click here to ask your question

Vokera combi boiler 20-80 RS flowmatic-the pilot light keeps going off?

There doesn't appear to be any pattern to it and it's usually when the heating/ hot water is not being used. it is now getting very difficult to reignite the pilot light - trying many times before this will remain on. Any suggestiosn?
Thanks
Stella
Stella Cox, October 2007
If the fan does not run slowly when just the pilot is lit then the flame will suffocate, until enough oxygen has made it into the combustion chamber it is going to be difficult to re light.

When you turn on the electricity to the boiler with no CH/hot water demand you should hear the fan start slow running.

If you dont hear the fan, then a faulty microswitch, dry joint or open circuit slow run resistor may be causing the fan not to run and remove pilot flame combustion products.

fred, November 2007
needs a new thermocouple. get someone qualified to fix it, not a diy job

jim, October 2007