Ian Scott asked ... Remove cover off gas boiler?    |    wendy asked ... Old Creda Solar Plus Cooker will not come on?    |    Nick asked ... Oven spark Continuing after lit?    |    Andrew asked ... Jcb cordless 20v combi drill?    |    marc asked ... La machine 1 type 813?    |    Click here to ask your question

vaillant open vent ecotec plus 418 fault 28?

boiler fired up when first turned on then turned it off when turned on again no egnition two codes come up s98 and f28
jonnie, November 2007
Quote from Service manual (available as pdf from vailliant site)
Fault 28 - Fault in the gas supply such as:-Gas meter or Gas pressure detector defective. Air in gas, gas pressure too low. Fire detection tap has disengaged. Fault in the gas valve, wrong gas setting, Igniter (ignition transformer, ignition cable, ignition plug) defective. Ionisation currnent stopped (cable, electrode), Faulty earthing in appliance, electronics defective.

S98Flow/Return sensor check is running. demand (DHW or Heating) is blocked.

Peter kay, December 2007