Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

Jaguar 28 Boiler?

I have a problem with the central heating on my boiler - Jaguar 28. The hot water runs fine but nothing happens when the CH should run. All the while it has not displayed any of the Jaguar fault message codes.

I have switched off and re-started the boiler - it goes through the usual procedure and then goes silent. CH doesn't work but DHW does.

The radiators all have TRVs except one in the "drying cupboard" next to the boiler cupboard which hasn't. It is permanently open for drying purposes and as a "by-pass" radiator.

As far as I can work out the pump does not appear jammed and there is plenty of water in the system.

Any suggestions welcomed
Alan, February 2008
Thanks Perry525,

I have checked the pump and it appears to be turning okay. There is no room thermostat - all radiators have TRVs. Still no joy.

Alan.

Alan, February 2008
First of all take off the front of the pump and putting a large screwdriver in the slot check that it spins.

Use a neon tester to see if you have power at the room thermostat and that the contact is making OK, ie: power out when on.
Check for power at the pump, is it getting through.

Perry525, February 2008