Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    wendy asked ... Old Creda Solar Plus Cooker will not come on?    |    Click here to ask your question

How can I fix my pressure?

The pressure in my boiler keeps increasing above 2.5 how do I fix this
Helen Allison, February 2008
what are you going on about.
a boiler dosen't have a ball valve.
and that is nothing to do with the pressure rising.

is it rising when heating on then fall again when heating off ?
or does it rise all the time ?

hi-spec plumbing & heating., February 2008
I think the ball valve that shuts off the mains top up, has been fitted the wrong way round (it will have an arrow on the side showing which way the main pressure should be pushing)
If so, check that there is/is not another tap in the line, if there is, has it been left turned on? If there isn't, then you need to drain that part down, turn the valve round and refill.
If you are happy to work with plumbing, then replace the ball valve with a proper tap that will turn off the water regardless of which direction has the highest pressure.

Perry525, February 2008