GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

How to solve Vokera Linea 24 slow pressure rise?

I've had the above boiler since about 2001, and it's been working well. The only thing I've changed since is the pump.

A few weeks ago I notice a slow build up of pressure in the system, and I've had to routinely bleed off excess water to bring the pressure back down. My plumber suggested that there may be a fault it the filling-up loop, but after I disconnected this the problem IS still present. I would be very grateful for any thoughts on what is causing this, and what I can to do about it?
Erol, May 2008
Hi, I haven't the manula for this exact boiler here, but I will asume it is a combi.

There may be a small leak from dhw to system water across the dhw heat exchanger, this would lead to a pressure rise even if the filling loop was disconnected.

T, May 2008
link Click here to see other fixes for Vokera.