Melodie asked ... How do I remove and change the basket? Duratech Identity Gu?    |    Kathy asked ... Samsung ER-4915?    |    Mark asked ... Oven door removal?    |    Jt asked ... Where to buy mt270x petrol cap?    |    Jo asked ... How to engage clutch on old sewing machine to engage needle?    |    Click here to ask your question

How to solve Vokera Linea 24 slow pressure rise?

I've had the above boiler since about 2001, and it's been working well. The only thing I've changed since is the pump.

A few weeks ago I notice a slow build up of pressure in the system, and I've had to routinely bleed off excess water to bring the pressure back down. My plumber suggested that there may be a fault it the filling-up loop, but after I disconnected this the problem IS still present. I would be very grateful for any thoughts on what is causing this, and what I can to do about it?
Erol, May 2008
Hi, I haven't the manula for this exact boiler here, but I will asume it is a combi.

There may be a small leak from dhw to system water across the dhw heat exchanger, this would lead to a pressure rise even if the filling loop was disconnected.

T, May 2008