GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

Problem with Baxi Solo 3 PFL Boiler?

Hi

We have not long moved into a property with a Baxi Solo 3 PFL Boiler. Last week we noticed we had no hot water.
When we turn the boiler on, the 'boiler on' light flickers continuously, the fan light comes on, and then nothing else.
Does anybody have any idea what we can try? I have turned the switch all the way off and waited and turned it back on, nothing, and turned the fuse on and off at the fuse box. Any help would be greatly appreciated.

Thanks

Roy
Roy Healey, August 2008
... correction: that should be Honeywell type VR 4601T, not VR4061T. Good luck resolving the problem. PS: when you solve the problem, I would appreciate if you posted the solution as an answer on this web page. Thanks, Barry

Barry Moynihan, Dublin, August 2008
Hi Roy,

Accidently came across your message...

I have a Baxi Solo 3 PFL since April 2003, with only the one serviceman call-out to date, namely:

I had a similar problem to the one you describe (water not being heated) in Sept 2006. The first serviceman fitted a replacement air pressure switch at a part cost of Euro 62, but 3 days later the problem recurred. The second serviceman fitted a replacement Honeywell type VR4061T switching unit at cost of Euro 140 from Interparts. Because the first serviceman had wrongly diagnosed the problem, I was refunded the cost of the air pressure switch and the call-out cost of both visits.

As the second serviceman told me (& I wrote it down, hence the detail) if all previous lights come on BUT the burner light does NOT, the problem is most likely a faulty air pressure switch. If, however, the burner light DOES come on, there is definitely NOT a problem with the air pressure switch. After some testing of the system, he fitted the replacement Honeywell unit because ALL lights did come on, but he found that the gas did not flow.

Hope this could help, now or in the future

Barry, Aug 30, 2008

Barry Moynihan, Dublin, August 2008
link Click here to see other fixes for Baxi Solo 3.