GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

Prima F40 - No hot water or heating?

Hi,

My Prima F40 boiler is doing nothing when hot water and/or heating is turned on. The heating pump kicks in but there is no activity in the boiler at all. No fan, no pilot light, no relay activity, no ignition... Nothing.

Last september I replaced the PCB capacitors as I was getting the fan cycling issue and it hasn't missed a beat since.

Any suggestions on where to start with this would be much appreciated.

Cheers,
Jon.
Jon, February 2009
Hi,

Thanks for the replies. I've fixed it :)

I was checking the fan voltage as per Mr K's suggestion and got nothing. I poked the connector and the board arked on the underside. I Removed the PCB and found that one of the PCB connector pins had come loose and broken the track. Resoldered it and and it's working again.

Thanks again for the replies.

Jon., February 2009
Try reset button

a, February 2009
Is pump wired to pump live in boiler pump circuir than check 240 on fan or fan plug is pulled out on pcb if all ok than seems to be pcb

Mr K, February 2009