Andrew - C asked ... Stannah 400?    |    Liam asked ... Belts for old WEBB Mower?    |    Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    Click here to ask your question

I have a combi boiler and hardly any hot water is coming out of taps ?

When I urn the hot taps on or the shower there is a big clunkng noise and then the water pressure drops and I only get a trickle of water out of the tap. Can anyone help?
Nic, September 2009
sounds like a glowworm swiftflow they rattle like they have gravel inside on hw demand after initial release of water pressure they trickle due to the heat exchanger being scaled up. if its a fair age mind you. otherwise check taps if only one tap then sus tap. if newish ignore this

gilo, September 2009
It is, a Powermax boiler, about 12 years old. Not showing much max power at mo!!

Nic, September 2009
restriction in the pipework or plate heat exchanger most likely. what type of boiler is it?

Ian, September 2009
Sorry the above question should say turn not urn

Nic, September 2009