andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

Worcester heatslave 20/25 fault with fan?

Hi, my boiler fan is running all the time, even when hot water / central heating is off. Everything else seems to be working but the fan isn't switching off ? Can anybody advise.
Nick, December 2009
Some early Heatslave oils had a post purge kit fitted to ventilate the combustion chamber when the burner shut down, it sounds like the timer has failed causing the burner motor to run constantly the timer is fitted in the boiler control panel - left hand side, replacement costs about £90

www.elanar.co.uk, December 2009
link Click here to see other fixes for Worcester heatslave 20/25.