GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

potteron profile 100e, hot water, no central heating ?

can anyone shed some light on the matter? we have no problem with the DHW system, but we have no CH at all. What was happening is, the boiler would light up then it would go out out after about 10-15 seconds then not come on again for about 5-10 mins(times are aprox only) so from this you can see no CH.
slinky, January 2010
profile is not a combi, so it will be either a faulty zone valve, or a faulty pump if you have a gravity hot water system.

Ian, January 2010
The diverter valve is stuck in DHW mode. May be caused by a dripping DHW tap, or may need a new diverter valve.

Henry, January 2010