Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

heating?

have just moved house,the boiler is britony combi 80 boiler.have not tried heating as the pressure guage is reading zero.how easy is to attach filling loop and fill system.
paul stott, July 2010
should already have one. Look under boiler for 2 chrome taps-one on the cold main and one on the flow or return pipe from the boiler-the loop consists of a flexible connection that you put between these taps to fill the system. Fill the system to the recommended pressure-usally 1-1.25 bar but check with manufacturers instructions. Then switch off loop and remove-Some boilers have an in built loop-check instructions if this boiler is one of these-in all cases be careful and if in doubt- do nowt!

gb, July 2010