narnia asked ... Matsui ct-111ss?    |    Jason asked ... How to fix handset problems ( intercom ) and access control?    |    andy asked ... Samsung VP-D60 camcorder?    |    Shopper asked ... Poor Renault Radio Reception?    |    reg bardle asked ... Lg 7kg dd?    |    Click here to ask your question

high pressure ikon combi?

the pressure keeps going up over 3bar and now the boiler is starting to smell a little! what can i do to try and sort it out?
sean green, November 2010
Ensure the filling loop is shut, even to the point of removing the braided hose.
If this doesn't cure the problem and it continues to rise, there is a problem with the domestic heat exchanger 'mixing', replacement of the DHE being the only solution, these boilers (only seen a few) use the Worcester cdi DHE (see question DIRECTLY below this one).

Carefree, November 2010