andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

how can i fix my combi boiler worcester bosch 24 j?

I have a worcester 24 j combi boiler and its suddenly packed up the fan and pump run but it doesnt ignite any clues
mrs s mcmanus, November 2010
If it's the older 24junior and the pump then fan runs and then it seems like it's going to ignite but then the red light starts flashing it probably will be the low water pressure switch on the top right hand side of the heat exchanger that's blocked if the fan runs for about a second it will probably be the pcb....

Gary, November 2010
If it's the condensing model (Greenstar Junior 24) check the 3/4" dia white condensate pipe isn't blocked. The condensate that runs through this pipe is prone to freezing in very cold weather.

Hope this helps.

CMac, November 2010