narnia asked ... Matsui ct-111ss?    |    Jason asked ... How to fix handset problems ( intercom ) and access control?    |    andy asked ... Samsung VP-D60 camcorder?    |    Shopper asked ... Poor Renault Radio Reception?    |    reg bardle asked ... Lg 7kg dd?    |    Click here to ask your question

circulation problems?

Is it possible for a pump to be working but not at full power.Some of my rads furthest away from the boiler barely get hot. I have cleansed the system with sludge cleaner so should be clear.
roy, December 2010
Your rad's may need balancing, especially if you drained down to add the cleaner, close the rqads that are hot n wait for the cold ones to warm then open the others a touch, hope this helps

Stag Heating TMSGAS, December 2010
You may have air in th system. if so you need to bleed the rads with a rad key or flat ended screw driver on each rad, do not remove the bleed screw just open it up till you hear the air coming out then followed by water if when you open the screw and water comes out this rad is ok. The system should run at around 2 bar, top up the system and bleed the rads to get the air out of each rad. Do not forget to top up system after each rad bleed.
Hope this helps

paul, December 2010