3 hours ago Karen asked ... Royal 480nt cash register?    |    andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    Click here to ask your question

pressure guage showing zero?

how do i adjust pressure
davie mack, December 2011
you will have to refill the system usually 1 to 1.5 bar.take a look around or ontop of the boiler for a silver flexi refill pipe.it is possible that this pipe is already connected to the system.one end of the pipe is connected to the water supply and other end is connected to the water inlet valve on the boiler.when connected simply open both valves and fill system to required bar/pressure.run the boiler and bleed radiators if bleed valves are fitted.

ozone, December 2011