Jo asked ... How to engage clutch on old sewing machine to engage needle?    |    Jacky asked ... Miele Vacuum cleaner?    |    Ben asked ... Toyota Yaris French or Japanese?    |    Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Click here to ask your question

pressure guage showing zero?

how do i adjust pressure
davie mack, December 2011
you will have to refill the system usually 1 to 1.5 bar.take a look around or ontop of the boiler for a silver flexi refill pipe.it is possible that this pipe is already connected to the system.one end of the pipe is connected to the water supply and other end is connected to the water inlet valve on the boiler.when connected simply open both valves and fill system to required bar/pressure.run the boiler and bleed radiators if bleed valves are fitted.