GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

Baxi megaflow E168 Error code?

Boiler will ignite when below 30oC but when water temp any hotter it will not reignite even when reset until the temp drops.Reluctant to fit PCB if it could be a temp sensor problem.
Alex, February 2013
u can ring baxi and ask them for the reading on the sensor . then u or an engineer can check the sensor with a multimeter to see if u are getting the correct resistance to eliminate if its a sensor fault. but from what u are saying i would think its a sensor fault.

kash, February 2013
link Click here to see other fixes for Baxi.