Jo asked ... How to engage clutch on old sewing machine to engage needle?    |    Jacky asked ... Miele Vacuum cleaner?    |    Ben asked ... Toyota Yaris French or Japanese?    |    Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Click here to ask your question

Baxi megaflow E168 Error code?

Boiler will ignite when below 30oC but when water temp any hotter it will not reignite even when reset until the temp drops.Reluctant to fit PCB if it could be a temp sensor problem.
Alex, February 2013
u can ring baxi and ask them for the reading on the sensor . then u or an engineer can check the sensor with a multimeter to see if u are getting the correct resistance to eliminate if its a sensor fault. but from what u are saying i would think its a sensor fault.

kash, February 2013