Eed asked ... Brother KR850?    |    Lynne asked ... Disable Alarm Scantronic 9800?    |    Ron Minadeo asked ... Table won't close all the way?    |    Cam asked ... How can I fix my Bison 50 stairlift?    |    Alfred Briffa asked ... How to build a battery conversion adapter?    |    Click here to ask your question

Pcb ?

How do I replace a pcb on my ideal he isar 24 boiler
Archie york, August 2015
How do you know the old pcb is faulty?
What tests have you done on the old pcb to prove it is dead?
Have you checked the pcb 3.15amp fuse?
The pcb on an isar is one of the easiest pcbs to change
Can be replaced in under 2 minutes
The molex connectors are idiot proof
Impossible to mix up
The only trouble most people have are inserting the jumper links to configure the pcb to the boiler model

Q, August 2015
switch off electric supply to boiler get to control panel , undo cover of PCB ,take photos of connection
take out connection one by one all connection are fitted lock in push fit you need small screw driver to unlock connection all connection are different so cant go wrong or mark it with colours ,once connection out undo screws holding PCB ,down lord ideal stelrad manual

ltd, August 2015