GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

chaffoteaux boiler pressure keeps rising?

pressure keeps rising over 3 bar sometimes upto 4.
had filling loop replaced and heat echange but has not fixed problem.chaffoteaux sterling ff aprox nine years old
s mankowski, January 2007
the diaphragm is probably punctured

grijzehond, February 2009
Drop the boiler water pressure to zero .using a foot pump increase pressue in pressure vessel to 0.9 bar .reduce boiler water pressue to zero if it increases.when pressure in pressure vessel is 0.9bar and boiler water pressure is zero,increase boiler water pressure to 1.2 bar .bleed the radiaters.

Pravin, January 2007
expanssion vessel is the problem

hi-spec plumbing, January 2007