andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

baxi 100 e system boiler?

boiler reaches temp on stat pump runs on for a couple of minutes then stops will not fire back up unless i turn prog d/h/w of then back on cons no hot water
wwernham, July 2007
Sounds like the 2 or 3 way motorised diverter valve is sticking and allowing flow of water which the sensor inside the boiler needs to tell it to fire up. What you're doing when switching d/w/h to off then back on is to drive the motor (airing cupboard) from one side to the other allowing water flow. Hope this helps?

Chris, July 2007