GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

The water pressue is zero on my Glow worm swift flow boiler?

The pressure reads zero and the red warning light is flashing. How can i bring the pressure back.
Mark Roberts, October 2007
PUT SOME WATER IN!
UNDERNEATH THE BOILER WHERE ALL THE PIPES ARE YOU WILL FIND A (SHOULD) BRAIDED FLEXIBLE HOSE.
AT THE END OF THIS HOSE OR MAYBEE EVEN AT EACH END OF THE HOSE YOU WILL FIND A TAP OR SCEWDRIVER SLOT TYPE VAVLE.
THIS IS CALLED THE FILLING LOOP.
OPEN THE TAP/VALVE, BOTH IF THER ARE TWO AND THE PRESSURE GAUGE ON THE BOILER WILL GRADUALLY RISE.
WHEN YOU GET TO 1-BAR OR 15 PSI CLOSE THE TAP/VALVE.

IF THE BOILER HAS A PRESSURE OF ZERO THEN YOU HAVE A LEAK SOMEWHERE ON YOUR HEATING CIRCUIT.

AVALON, October 2007