Jo asked ... How to engage clutch on old sewing machine to engage needle?    |    Jacky asked ... Miele Vacuum cleaner?    |    Ben asked ... Toyota Yaris French or Japanese?    |    Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Click here to ask your question

Pilot light has gone out?

I have a Potterton Netaheat 10/16 boiler. The pilot light has gone out. I have had British Gas look at it and they say the gas valve has packed up and they cannot get the spare part and the only option is to have a new boiler. is this correct?
Edward Coomber, October 2008
You will struggle.The Netaheat never had a pilot it was fan flued and is now obsolete.A gasvalve will cost a small fortune even if you can get one anyway.Its probably the solenoid on the valve that has gone but the valve was a one off to this kind of boiler so you cant fit any other type.

Tony S, October 2008
link Click here to see other fixes for Potterton.