GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

How can I fix my fertility boiler ?

My boiler.keeps flashing f5 and p1 and won't fire up so we have no hot water or heating
Liam Jackson, December 2016
Post the correct name, for starters.

I believe you have a FERROLI boiler. Not sure about the exact model, tjhough, since you didn't mention it.

Have you checked the manual? (should be easy enough to find online, once you search for the right model and make)

The best advice and by far the safest is: Get a Gas Safe certified engineer to look at it.

If its a FERROLI F30b, I understand the most common related faults on these are

• Fan stiffening up.
• A wrong flue restrictor - On a ferroli this can suddenly cause a problem even if its worked great for a couple of years.
• Fan relay on the PCB.

There's other stuff it could be of course but there's where I look first on these.

Read more: http://www.diynot.com/diy/threads/ferroli-f30-b-f5-issue-fixed.389870/#ixzz4TEwt17in

On the Ferroli Optimax the F5 error code is:

Fan problem

• Tachometer signal

interrupted, fan connection

• Fan damaged, debris in fan

Possible Solution

• Check the wiring and fan

• Check the fan, clean debris

Hope this helps you to get started. Good Luck.