We have 73 questions about fixing 'grundfos'

Grundfos water pump Model CEIP65?

The pump stars for a second and then stops. When I press the RESTART button it does the same thing. How do I make the motor running.


Problem after changing ch pump on a grundfos pump plan?

I have now changed the central heating pump twice in the last week on my grundfos pump plan installation using grundfos ups 15 50 heads . The problem both times is that they worked perfectly and total ... more


done

Changing Grundfos UPS 15/50x18?

I have an engineer coming to look at my system as the lower floor radiators have ceased to warm up. I suspect its the pump and the engineer says the system has to be drained down to change the pump bu ... more


grundfos selectric 15-50?

Central heating working ok but hot water only luke warm. Large screw ! in center of pump is pointing to '130' on face.Is this correct ? System has been running for 3 yrs with annual service. Is it ... more


done

Can I stop the start-up noise from my Grundfos UPS 15-50?

My Grundfos UPS 15-50 pump is only 2-3 years old and still performs very well EXCEPT when starting up each time when it makes a horrendous grating noise for 15 to 20 seconds. Is this likely to be sim ... more


done

Reillo oil burner RDB1 50/70 problem?

Can anyone help. I have just moved my oil tank as the new house I brought had the tank 6" from the house. All went well and have pumped the oil back into the tank. Had an earth fault with old grundfos ... more


done

water is filling the header & expansion tank via the feed pipe to the pump?

Over the last few weeks I have noticed that the overflow pipe to the header tank has been dripping, but I have proved that the water is coming into the tank via the outlet pipe (I've emptied the tank ... more


done

Problem refilling CH system after fitting Grundfos 15-50 130 selectric pum?

I have had to drain my CH system to fit a new radiator. Problem occurs when refilling.It only takes about 25% of the normal amount of water to fill it before it backs up to the header tank. There seem ... more


done

Hot water from boiler filling expansion tank?

I have an old type CH/HW system with storage cylinder in airing cupboard and Bermuda 552 back boiler. I noticed that hot water from boiler going to pump (Grundfos UPS 15-60) also fills up expansion ta ... more


done

grundfos 15/50 pump ?

i have 2 of these pumps fitted to a gledhill biolermate11 c/h h/w the h/w pump is not circulating hot water causing gurgling and banging pipes swpped both pumps around and the h/w pump worked so ... more


done

Replacement capacitor?

Where can I get a replacement capacitor for my GRUNDFOS 15/60


done

how can i fix a leak thats behind the grundfos pump where it connects to co?

i niticed my boiler was leaking where the Grundfos pump connects to ciopper pipe behind it. could it be a seal that has gone?


how can i stop my grundfos pump jamming ?

My pump has jammed and i need to know if i have to stop the flow of water into the pump and out again when i attempt to manually start the pump by using a screwdriver to turn the inside of pump. Wil ... more


done

how can i check my honeywell v4073a 3-way diverter valve?

many thanks to brian for his earlier help further to my earlier request i have checked my grundfos selectric pump & it is working as it should so i now suspect either the manual roomstat or the divert ... more


done

is my c/heating pump working?

i live in a bungalow my water is getting hot ok (gravity fed?) myradiators do not get warm how do i check to see if my grundfos selectric up 15-50 central heating pump is working? thanks in advac ... more


done

Grundfos shower pump?

I have the above shower about 6+ years old, model ANH BP65S, fishy burning smell when used, but still works OK. Can anyone tell which modern day model would replace it. I want to be able to take it ... more


grundfos selectric ups 15-50?

it was all working fine until this morning, boiler is supplying plenty of hot water but rads are cold. on the side of the pump there is a plastic disc that turns with a flat head screw driver. when tu ... more


done

the pump stays on after the heating has switched off?

my grundfos selectric pumps is staying on after the timer for the heating system has switched off.


done

Grundfos UPS 15 Circulation Pump Fault?

Our Circulation pump has become very noisy over the past few days. The radiators seem to be working ok and the hot water is still being provided but the pump is making this aweful clockwork like noise ... more


done

Grundfos Selectric UPS 15/50 Central Heating Pump started whinning?

My above pump, circa 12 years old, has started making a high pitched whinning noise from time to time. I think this happens when it has been running for a while. When the pump stops the noise stops. ... more